Bosch Security Systems Operating Instructions V 2.5 | 2007.6
rate. A value of 31 results in a very high refresh rate and lower
image quality.
I-frame distance
This parameter determines the number of inter-coded frames
between two I-frames.
7.4.3 JPEG posting
You can save individual JPEG images on an FTP server at certain
intervals. You can then retrieve these images at a later date to
reconstruct alarm events if required.
JPEG format
Select the resolution you wish the JPEG images to have:
Small 176 × 144/120 pixels (QCIF)
Medium 352 × 288/240 pixels (CIF)
Large 704 × 576/480 pixels (4CIF)
File name
You can select how file names will be created for the individual
images which are transmitted.
Overwrite: The same file name is always used and any
existing file will be overwritten with the current file.
Increment: A number from 000 to 255 is added to the file
name and automatically increased by 1. When it reaches
255 it starts again from 000.
Date/time suffix: The date and time are automatically
added to the file name. When setting this parameter,
please ensure that the date and time of the unit are always
correctly set. Example: the file snap021606_124530.jpg