7.5 Camera settings
7.5.1 ALC
Video level
Adjust the video output level (-15 to 0 to +15).
Shutter
AES (auto-shutter) - the camera automatically sets the
optimum shutter speed for manual iris lenses. The camera
tries to maintain the selected shutter speed (1/60 [1/50],
1/100, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/5000, 1/
10K) as long as the light level of the scene permits.
FL - flickerless mode avoids interference from light sources
(recommended for use with video iris or DC iris lenses
only).
i
NOTE!
If the camera is in monochrome mode, all color related menu