Bosch Power Tools NWC45510P Digital Camera User Manual


 
Dinion IP Configuration via the browser | en 75
Bosch Security Systems Operating Instructions V 2.5 | 2007.6
example when connections are initiated by a controlling system
such as VIDOS or BVMS. The camera connects to all devices
protected by the same general password. To define a general
password:
1. Select 10 in the Number of Destination IP-address list
box.
2. Enter 0.0.0.0 in the Destination IP-address field.
3. Enter the password in the Destination password field.
4. Set the user password of all the devices to be connected
to this password.
Setting destination 10 to the IP-address 0.0.0.0 overrides its
function as the tenth address to try.
Destination port
Choose the browser-port, depending on the network configura-
tion. Port 443 for HTTPS connections is only available if the On
option in SSL encryption is selected.
SSL encryption
SSL encryption can be used to protect data, such as the pass-
word used for establishing a connection. If you select On, only
encrypted ports are available for the destination port. SSL
encryption must be activated and configured on both sides of a
connection. The appropriate certificates must also have been
uploaded (see “SSL certificate upload” on page 96). You can
configure and activate encryption for media data (video, audio,
metadata) on the Encryption page (see “Encryption” on
page 89).
Auto-connect
Select On if an active connection should be re-established auto-
matically to one of the previously specified IP addresses after
each restart, connection breakdown or network failure.
i
NOTE!
Stream 2 is always transmitted for automatic connections. This
should be taken into account when assigning the profile.