Example 2:
Position: Middle
Selected range = Enable, Start = 0 mm, End = 0 mm
Multifeeds are detected for the area in light blue.
Example 3: (Bad example)
Position: Middle
Selected range = Enable, Start = 100 mm, End = 102 mm
Since the detection range (length) is less than 5 mm,
multifeeds cannot be detected accurately.
When you use detection by overlapping, accuracy of multifeed
detection may drop if the documents are glued tightly or
attached together by static electricity.
35
300
Feed direction
Unit: mm
35
300
2
100
Feed direction
Unit: mm