Fujitsu M3099EX/EH Photo Scanner User Manual


 
M3099EX/EH OEM Manual 3-81
INTERFACE
SPECIFICATIONS
Operation error
This response indicates that the error related to operation
specification program occurs.
Byte 3
TEXT
Detailed error Information I
Byte 1
CNT
X'03'
Byte 2
RPS
X'55'
Detailed information I
Detailed information I gives details on errors in command/response
transmission and reception to and from the host computer.
b7 b0
00
The dither pattern or the overlay pattern or γ pattern
not registered was specified.
The bit or number of an undefined control register
was spedcified.
An operation was specified for a nonexistent option.
An undefined command was received.
Command sequence error
Read area specification error (*1)
*1: Although standard document size bit on control register 5 is on, (Bit 7 takes
"1" and bit 6 takes "0"), the size specifying bits (bits 0 to 4) are not defined.
Control register contents do not change even if the above errors are
detected.