3-38 M3099EX/EH OEM Manual
IMAGE CONTROL command
This command sets the scanner to the operation mode of the image
processing circuit.
Byte 1
CNT
X'0X'
Byte 2
CMD
X'5A'
Byte 3
TEXT
Image control
register start number
Byte 4
or later
Image control
register
b7 b0
(Byte 3)
Image control register No.
0
Front-side/back-side select
b6
0
1
Description
Selects image control register A (front-side)
Selects image control register B (back-side)
Note: If this command is sent to the scanner without image
processing option (IPC II), the scanner sends "Operation
error" as response.