3-52 M3099EX/EH OEM Manual
RETURN SENSE command
Same as SENSE command. But the scanner does not report the
temporary error.
Byte 1
CNT
X'02'
Byte 2
CMD
X'42'
IMAGE MODE SENSE command
This command is valid for the scanner with the image processing
circuit. When the scanner receives this command, the scanner
reports the image processing mode of the main window and number
of pixels (Unit: Byte) per line in the X-direction. By specification
byte 3 of this command, the front or back-side image status can be
selected.
Byte 1
CNT
7 6 5 4 3 2 1 0
0 0 0 0 0 0 0
0 : Front-side image status received
1 : Back-side image status received
X'03'
Byte 2
CMD
X'43'
Byte 3
TEXT
INQUIRY command
When the scanner receives this command, the scanner reports a
device information report.
Byte 1
CNT
X'02'
Byte 2
CMD
X'40'
Byte 3
or later
—