Fujitsu M3099EX/EH Photo Scanner User Manual


 
M3099EX/EH OEM Manual 4-33
BASIC
OPERATION
7 To re-install lamp/heater,
reverse procedures in item
4 above.
Note:
Make sure to rotate lamp in
the direction as shown in the
left figure.
8 Align the lamp unit with
the grooves on the machine
and insert the lamp unit
completely. Then, turn the
thumb screw completely to
avoid cover open error.
9 Attach the side cover.
Replace the roller ASY as follows:
WARNING
Wait at least 3 minutes after turning off the power before replacement.
Roller ASY
Replacement
Upper transport unit
Operator panel
Lever
1 Turn off the power switch.
2 Open the upper transport
unit. (See page 4-2)
Window
Socket
Power switch
Thumb screw
Lamp unit