CSS components Hot-plug components
Figure 22: Unlocking and removing the power supply unit
Ê Remove the cable of the defective power supply unit.
Ê Briefly press the green point (1).
This releases the locking lever.
Ê Rotate the locking lever in the direction of the arrow (2).
Ê Completely remove the defective power supply unit at the locking lever from
the slot (3).
V CAUTION!
Never leave the slot for the power supply unit empty for more than two
minutes during operation. Otherwise, excessive temperatures could
damage system components.
Ê Slide the new power supply unit with open locking lever into the empty slot
until it clicks into place.
Ê Press the locking lever on the housing until it engages.
I Make sure that the new power supply unit engages correctly in the
mounting location and is locked in position.
This is the only way to prevent the power supply unit from sliding out
of its mountings and being damaged during transportation.
Ê Connect the newly installed power supply unit.
1
3
2