Hasselblad 70480533 Digital Camera User Manual


 
66
H4D
4b
3b. Alternatively, you can position the central spot in the view-
nder over an area that you consider should be rendered as
neutral in color in the image (a ‘grey card’ or even a sheet
of white paper is ideal) and make a test capture (ensure the
exposure is approximately correct otherwise you will get a
warning message).
A small rectangle appears on the display marking that parti-
cular area. Calculations then take place automatically so that
the following shots use the area chosen as the new ‘white
balance’ standard. Using this method you can also read o
the screen what the color temperature of the light source has
been judged to be in degrees Kelvin.
4b. Press the
MENU
button to exit the menu system and keep the
setting.
To make a rapid User Button white balance setting:
(Please note: this function works when using a CF card only)
1. Assign the
User Button
(or
AE-L, STOP DOWN or M.UP
button)
to activate
Grey balance exp.
(see under Customizable
button function list for details.
2. While framing the centre spot in the viewnder over a
neutrally colored surface, press the assigned button.
A small rectangle appears on the display marking that
particular area. Calculations then take place automatically
so that the following shots use the area chosen as the new
‘white balance’ standard.
Tip
You can select batches using just the
(+) and (-) buttons while browsing
images. This method also enables
you to select a batch as you zoom
in from thumbnails to preview. See
Navigating Batches for complete
details about this method .
Note
New settings are retained even
when the camera has been turned
o and re-activated, so don’t for-
get to make new settings when
required.
White Balance Shot screen
appears after test capture to
illustrate the area chosen for
white balance calculation.
3b