Axis Communications Q7411 Camera Accessories User Manual


 
AXIS Q7411 Video Encoder
Events
Triggers
Available action rule triggers and conditions include:
Applications – Use installed applications to trigger the rule. See Applications on page 32.
- VMD3 – Trigger the rule when AXIS Video Motion Detection detects a moving object. See AXIS Video Motion
Detection.
Detectors
- Audio Detection – Trigger the rule when audio is detected. See Audio Detection on page 31.
- Tampering – Trigger the rule when tampering is detected. See Camera Tampering on page 31.
Hardware
- Video Signal – Trigger the rule if video signal is lost.
- Network – Trigger the rule if network connection is lost or restored. This can for example be used to start
recording to the SD card.
- Temperature – Trigger the rule if the temperature falls outside or inside the operating range of the product. This
can for example be used to send maintenance notications.
Input Signal
- Digital Input Port – Trigger the rule when an I/O port receives a signal from a connected device. See I/O
Ports on page 58.
- Manual Trigger – Trigger the rule using the Manual Trigger button in the Live View page. See Controls on
the Live View Page on page 11 . This can for example be used to validate actions during product installation
and conguration.
- Virtual Inputs – can be used by a VMS (Video Management System) to trigger actions. Virtual inputs can, for
example, be connected to buttons in the VMS user interface.
PTZ
Storage
- Available – Trigger the rule when the storage device is unmounted or removed. This can for example be used to
send maintenance notications.
- Disruption – Trigger the rule if storage problems are detected, for example if the storage device is unavailable,
removed, full, locked or if other read or write problems occur. This can for example be used to send maintenance
notications.
- Recording – Triggers the rule when the Axis product records to the storage device. The recording status trigger
can be used to notify the operator, for example by ashing LED lights, if the product has started or stopped to
record to the storage device. Note that, this trigger can be used only for edge storage recording status.
- Full – Trigger the rule when the storage device is full. Under normal operation, the oldest recordings will be
overwritten to prevent the storage device from becoming full.
- Locked – Trigger the rule if the storage device is locked (write protected).
System
- System Ready – Trigger the rule when the product has been started and all services are running. This can for
example be used to send a notication when the product restarts.
Time
40