Tamper Map
This button requests a map of all the
devices on this transponder (receivers
or alert units) that are reporting a
tamper condition to the system. The
current troubles list is automatically
updated.
Acknowledge
Clicking this button removes all
restored troubles from the current
troubles list.
AC Loss Map
This button requests a map of all the
alert units on this transponder that
are reporting an AC loss condition to
the system. The current troubles list
is automatically updated.
Refresh Data
Clicking this button updates all of the
transponder level data in this screen.
It does not update the device troubles
(use stress test or auto scan to update
the device troubles).
Reset Transponder Troubles
The Reset Transponder Troubles button
is used to reset all of the alarm, test
and message counters to zero, and to
remove any restoration reports.
Low Battery Map
This button requests a map of all the
alert units on this transponder that
are reporting a low battery condition
to the system. The current troubles
list is automatically updated.
3.3.11 Transponder Parameter Change
Screen
This screen allows parameters stored in
the transponder’s EEPROM memory to be
viewed and changed.
Figure 444: Transponder Parameter
Change Screen
Run Silent
If checked, the receivers and alert
units on this transponder do not sound
an alarm. This includes alarms received
during a communications failure with
the central console.
Optional Parameter
This is a future option, leave
unchecked.
Loop Communications
When this option is checked, the
communications to the transponders are
wired in a loop. The output from the
computer goes to the input of the first
transponder. The output from the first
transponder goes to the input of the
second transponder, and so on until the
output from the last transponder in the
loop goes to the input of the computer.
This form of communications allows
fiber optic communications to be used
(with third party fiber to RS-232
converters).
Enable Remote Key
If checked, the remote key supervised
input on this transponder is enabled;
otherwise, it is ignored.
Uses Proxim Radio
Only check this item if a Proxim radio
is used to communicate to the central
console.
Comm Fail to Siren Out
If this item is checked, the siren
output on this transponder activates
when a communications failure is
detected at the central console.
Verbose Point Reports
If checked, alarm and test reports
include average levels and packet count
information. This extra information is
for diagnostic proposes only and is not
required for system operation. Since
the additional data increases the
system traffic load leave this item
unchecked.
Test Min Level
This is the minimum receive level (1 to
255) a receiver must see before the
green light displays acknowledging a
successful test. Leave this item at
default (128).