Security Escort | Technical Reference Manual | 3.0 System Menus
and Screens
EN | 61
Bosch Security Systems | 6/12 | 38947D
In the Security Escort System used for
remote access
This screen sets up the remote access
parameters that allow remote connection
to a live Security Escort System.
Program all Comm port indexes in the
Transponder Comm Port Setup Screen to
none. In the Remote Comm Port Setup
Screen, set the network port to none
and set the modem to the Comm port of
the modem. The speed selected should be
greater than the speed of the modem and
the same as the speed selected for the
live system being called. In the Remote
Setup Screen, set the
master/slave/remote setting to remote.
In the Remote Connection Screen select
the Insert button and enter a name,
password, phone number, and three-
character file extension for this
system’s database files. Using a disk
written with the Backup command of the
system you desire access to, restore
the database files. Select the system
you just entered from the dropdown list
box in the Remote Connection Screen.
Exit the Remote Connection Screen and
select Restore Screen under the
Utilities Menu. Restore from the backup
floppy to each databases. When done,
you should also store a copy of the map
file in the Escort sub-directory under
the name MAP0.xxx, (where xxx is the
three-character file extension entered
earlier). After this is done, click
Dial to call the remote system. If
five, eight, or twelve characters of
the password match, you can enter.
Insert New
Clicking this button presents a blank
Phone Book Edit Screen to enter a new
remote access Security Escort System.
Edit
Selecting the desired Security Escort
System and then clicking this button
allows the existing Security Escort
System data to be edited.
Delete
Selecting the desired Security Escort
System and then clicking this button
deletes the data for the selected
Security Escort System.
Dial
Selecting the desired Security Escort
System and then clicking this button
attempts to connect the selected
Security Escort System. This selection
is only available on the remote
computer; it is not available on a live
Security Escort system.
Answer
This option is only available in a live
Security Escort System. Click this
button manually answers an incoming
call from a remote Security Escort
System.
Disconnect
Clicking this button drops a remote
connection. This can be done either on
the live system or the remote access
system.
Cancel
Clicking this button closes this screen
but does not disconnect a remote access
connection. At this point, you can
navigate the menus and screens on the
remote system as if you were at the on-
site slave computer system. To drop the
connection, return to this screen and
click Disconnect.
3.3.22 Phone Book Edit Screen
This screen edits existing entries and
adds new phone book entries for remote
system access.
Figure 577: Phone Book Edit Screen
System Name
This is a reference name for the
Security Escort System to be accessed
remotely. Use to select the desired
system to be accessed in the Remote
Connection Screen.
Phone Number
The phone number to be dialed to access
the Security Escort System. Enter a
comma for each 2 sec. pause desired.