Password Verify
For verification, reenter the same
password as above.
Disabled
If selected, this system serial port is
disabled (default).
History Filter Output
If selected, this system serial port
sends out whatever items are selected
in the History Filter Screen.
Video Switcher Control
If selected, this system serial port
sends out the strings programmed in the
Video Switcher field of the Transponder
Database Edit Screen’s Area data. Also
see Video Switcher Restore.
Remote System Control
If selected, this system is controlled
by another system through a proprietary
protocol. This setting can only be used
when two systems are specifically
designed to work together.
Video Switcher Restore
This string is output on any system
serial port programmed for Video
Switcher Control when all alarms are
restored. This string is output to the
video switcher to reset it to the
default displays. Up to twenty
characters can be entered. Control
characters can be entered as [^][A] for
control A.
Modem Init
This is the initialization string
output to the modem to set it up for
all communications except paging.
Normally, this setting does not need to
change. To allow changes to this
string, hold down the [SHIFT] and
[CTRL] keys when this screen first
opens. This string is specific to each
modem model. The default string should
work with most modems.
Modem Reset
This is the reset string output to the
modem. Normally, this setting does not
need to change. To allow changes to
this string, hold down the [SHIFT] and
[CTRL] keys when this screen is first
opened. This string is specific to each
modem model. The default string should
work with most modems.
3.3.21 Remote Connection Screen
This screen sets up the remote access
parameters that allow remote connection
to a live Security Escort System.
Figure 566: Remote Connection Screen
Set the modem port and speed in the
Remote Comm Port Setup Screen. The
speed selected should be greater than
the speed of the modem and the same as
the speed selected for the remote
system. Use the Backup command under
the Utilities Menu to create a database
backup to floppy. In the Remote Setup
Screen, assign a password and set which
computer (master or slave) is to answer
and the number of rings to answer on.
Also copy the map file from the live
Security Escort System. The map is in
the Escort sub-directory and is named
MAP0.EDB. There also may be other maps
under the names MAP1.EDB, MAP2.EDB, and
so on.