Security Escort | Technical Reference Manual | 3.0 System Menus
and Screens
EN | 50
Bosch Security Systems | 6/12 | 38947D
The illuminated LED’s indicate to
the service person standing near the
device that the receiver is actually
the one currently in the setup mode.
If the LED’s of the designated
receiver are not illuminated, there
is probably an error in the switch
settings of the receiver or an error
in the address in the Transponder
Database. To help resolve such
problems, the person at the central
console can command any device to
illuminate its LED’s and/or sound
its horn.
If the receiver in the Setup Mode
detects the maintenance alarm and if
the received signal is the strongest of
all receivers, the horn on the receiver
sounds briefly and the LED’s go off.
This indicates the receiver is
functioning properly and the receiver’s
address is set correctly in the
Transponder Database and on the
receiver’s switches.
Figure 477: Abort Button to Remove a
Device from the Setup Mode
The central console also confirms the
successful setup with an audible and
text message. The abort setup for this
MUX Point button disappears and is
replaced by Test On This MUX Point
Successful button. Click this button to
conclude the test on this point (see
Figure 48).
Figure 488: Confirmation of
Successful Setup Test
Auto Advance
If this box is checked, the central
console automatically selects the
receiver with the next higher point
address.
Horn - Siren
If this checkbox is checked, the horn
output of a receiver or the siren
output of an alert unit is turned on if
On is clicked, or off if Off is
clicked. If this checkbox is not
checked, the state of this output does
not change.
Green LED
If this checkbox is checked, the green
LED output of a receiver or the spare
output of an alert unit is turned on if
On is clicked, or off if Off is
clicked. If this checkbox is not
checked, the state of this output does
not change.