Bosch Appliances PT-400 Security Camera User Manual


 
Security Escort | Technical Reference Manual | 3.0 System Menus
and Screens
EN | 48
Bosch Security Systems | 6/12 | 38947D
Test Differential
This is the minimum difference in
receive level (1 to 255) a receiver
must be less than the loudest receiver
hearing a test before the green light
displays acknowledging a successful
test. Leave this item at default (64).
Alarm Min Level
This is the minimum receive level (1 to
255) a receiver must see before the
sounder and red light is displayed for
an alarm. Leave this item at default
(1).
Alarm Differential
This is the minimum difference in
receive level (1 to 255) a receiver
must be less than the loudest receiver
hearing an alarm before the sounder and
red light are displayed for an alarm.
Leave this item at default (255).
Byte
These are future options, leave at
default (0).
Spare
This is a future option (leave
unchecked).
Test Transmitter Type
Test Receiver 1
Test Receiver 1
Transmit Delay
Transmit Point
Load Delay
Tamper Load
These parameters are used for
engineering system load testing only.
Do not use in a live system, as they
can generate more traffic than a system
can handle; therefore, actual alarms
may be missed. Leave them at default.
Transponder
Selects the transponder the data is
presented for.
Previous
Returns to the previous transponder in
the system.
Next
Advances to the next transponder in the
system.
Send Change
Sends the changes made to the selected
transponder. Changes are not made to
the transponder EEPROM memory unless
this button is clicked.
3.3.12 Transponder Data View Screen
This screen is for engineering
evaluation of a transponder only.
Figure 455: Transponder Data View
Screen