Idle state
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is
to operate as an NC contact.
Operating mode
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm ends, select
Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select
10 s.
Relay follows
If required, select a specific event that will trigger the relay. The following events are possible
triggers:
Off
Relay is not triggered by events
Connection
Triggering when connection established
Video alarm
Triggering by interruption of the video signal
Motion alarm
Triggering by motion alarm, as configured on the VCA page (see Section 5.28 Advanced
Mode: VCA Event triggered, page 62)
Local input
Triggering by corresponding external alarm input
Remote input
Triggering by remote station's corresponding switching contact (only if a connection
exists)
Relay name
You can assign a name for the relay here. The name is shown on the button next to Trigger
relay. The Livepage can also be configured to display the name under the relay icon. You can
also use the name in the Forensic Search program function as a filter option for quick search
in recordings.
Trigger relay
Click the button to trigger the relay manually (for testing or to operate a door opener, for
example).
NOTICE!
The numbers in the lists of selectable events relate to the corresponding connections on the
camera, Local input 1, for example to the IN1 connection.
CAUTION!
Do not use any special characters, for example &, in the name.