JVC LST0819-001A Security Camera User Manual


 
32
Connection/Installation (VN-V686WPBU)
Connect the alarm signal cable to external
devices, such as a sensor or buzzer.
Note:
Noises from an external source may cause
the camera to malfunction even when the
cable used is within 50 m. In this case, move
the cable away from the noise source.
Alarm input signal
Connects to sensors such as infrared sensors,
door sensors, metal sensors and manual
switches.
To prevent noise from entering the internal
circuit, supply non-voltage contact signal to
the alarm input signal.
Do not supply voltage.
When the contact is short (MAKE) or open
(BREAK) on the menu, you can set it to
Alarm.
Supply such that the alarm signal continues
for at least more than 500 ms. The alarm
signal may not be recognized if it is less than
500 ms.
Alarm output signal
Connect to alarm devices such as alarm,
indicator, light or buzzer.
Alarm output signal is an open collector output
insulated with photo coupler.
During an alarm, it is ON.
As this terminal is polarized, be sure to
connect it such that the voltage of the + output
is higher than that of the – output.
It will be damaged if reverse voltage is
supplied.
Connecting the alarm signal
cable
Cable to use
Length of 50 m or shorter
UL1007, UL1015 or equivalent products
AWG#22 to AWG#18 or equivalent
products
Solder welding or
crimping
Insulating
tape
IN
COM
Rating:
Max. applied voltage: DC 20 V
Max. driving current: 25 mA
OUTPUT
COM
22