98
5. HUMID
WARNING lamp Lights for 90 minutes following the release of the
condensation detection after the condensation
formation was detected.
Indications on LCD
screen
“HUMID” display lights if condensation is
detected.
“HUMID” display flashes for an additional 10 to
90 minutes after condensation detection is
canceled.
Tally lamp Flashes 4 times per second for 90 minutes after
condensation detection is canceled.
Viewfinder “HUMID” display flashes from the time
condensation is detected until 90 minutes after
the condensation detection is released.
Alarm Sounds continuously (4 times a second during
recording).
Warning description Condensation has formed.
VTR unit operation The recording operation continues but if the tape
sticks, recording will stop.
For 80 minutes after the condensation detection
is released, the drum is rotated and no
operations are accepted.
Corrective action Stop the tape travel and turn off the power. If the
“HUMID” display fails to be cleared even when
the power is turned back on, wait until it clears.
6-3 Warning system
6-3-1 Warning description tables
When an error or a problem is detected immediately after the power is turned on or while an operation is underway, the
WARNING lamp and lamps inside the viewfinder serve to alert the user.
<Note>
Items are displayed in the following sequence of priority: WARNING lamp > tally lamp > warnings inside the viewfinder. The
display accords with this sequence when more than one error has occurred at the same time. However, WIRELESS RF may
not be displayed depending on the menu setting selected.
1. SLACK
WARNING lamp Flashes four times a second.
Indications on LCD
screen
“SLACK” appears and an error code flashes.
Tally lamp Flashes four times a second.
Viewfinder “SLACK” appears and an error code lights up.
Alarm Sounds continuously.
Warning description Motor, solenoid or other mechanism-related
trouble, etc.
VTR unit operation Operation is stopped. Power is turned off if
solenoid trouble has been detected.
Corrective action Check “6-3-2 Error codes,” and consult your
dealer.
WARNING lamp Flashes four times a second (for at least 3
seconds during recording).
Indications on LCD
screen
The code 11 display lights.
Tally lamp Flashes four times a second (for at least 3
seconds during recording).
Viewfinder REC WARNING display flashes (for at least 3
seconds during recording).
Alarm Sounds four times a second (for at least 3
seconds during recording).
Warning description Problem with the recording control signal.
VTR unit operation Recording continues but the signals may not be
recorded correctly while the warning remains
displayed.
Corrective action Rewind the tape or replace the cassette tape.
WARNING lamp Lights (during stop and standby OFF).
Indications on LCD
screen
The bar display that shows the remaining tape
amount starts flashing.
Tally lamp Flashes four times a second (during stop and
standby OFF).
Viewfinder
“
=
END” flashes (during stop and standby
OFF).
Alarm Sounds continuously (during stop and standby
OFF).
Warning description The tape has come to its end.
VTR unit operation Operation is stopped during recording, playback
and fast forwarding.
Corrective action Rewind the tape or replace the cassette tape.
WARNING lamp Lights.
Indications on LCD
screen
The bar display that shows the remaining battery
charge starts flashing.
Tally lamp Flashes once a second.
Viewfinder BATT LED lights.
Alarm Sounds continuously.
Warning description The battery charge is now depleted.
VTR unit operation All operations are stopped, and the tape is
unloaded. Only cassette tape eject is accepted.
Corrective action Replace the battery.
4. REC WARNING
2. BATTERY END
3. TAPE END
Chapter 6 Maintenance and inspections (continued)