Operating preset memory groups (PMEM GROUP) (continued)
Registering the preset memory to recall when in ALL
mode
1.
Press the MENU button to turn on its indicator.
2.
Open PM GRP1 menu [31].
1.PM GRP1 MODE
ALL
3.
Turn the F1 dial to display the “12. PM GRP1 ALL” item.
12.PM GRP1 ALL
PRE001
4.
Turn the F2 dial to select a preset number, and then
press the F2 dial to confirm the selection.
Recalling preset memory groups
Pressing a button to recall a preset memory group
Use PM GRP 1 to PM GRP 4 to recall preset memory groups.
PM GRP 1 to PM GRP 4 buttons USER ENABLE button
SHIFT button
1.
Press the SHIFT button to turn on its indicator.
2.
Press the PM GRP 1 button.
When the operation mode of PMEM GROUP1 is “SEPARATE”:
Simultaneously recalls each remote camera preset memory
registered to the “2. PM GRP1 1/10” to “11. PM GRP1 10/10”
items.
When the operation mode of PMEM GROUP1 is “ALL”:
The preset memory registered in the “12. PM GRP1 ALL” item is
recalled for all of the remote cameras registered to the unit.
zPreset memory is not recalled for a remote camera for which
“NoAsign” is set in CTRL TYPE menu [36].
z If the USER ENABLE button indicator is off, operation of the
PM GRP 1 to PM GRP 4 buttons is not possible. Perform
operation while the button indicator is on.
Note
Recalling a preset memory group by GPI input
A preset memory group can be recalled by contact input of the TALLY/
GPI connector on the rear panel of the unit.
<PIN numbers and preset memory groups>
Pin number
Signal
name
Corresponding preset memory group
19 GPI IN 1 PMEM GROUP 1
7 GPI IN 2 PMEM GROUP 2
20 GPI IN 3 PMEM GROUP 3
8 GPI IN 4 PMEM GROUP 4
⇒ “Control interface for external devices” (page 43)