Panasonic AWRP120GJ Camera Accessories User Manual


 
8
Manually adjusting the white balance (R and B gain
settings)
1.
As with the automatic adjustment, fill the screen with a
white subject.
2.
Connect the video output of the currently selected
remote camera to a waveform monitor.
3.
Press the WHITE BAL A button to turn on its indicator.
4.
Turn the R GAIN dial to select the R channel (red)
setting, and turn the B GAIN dial to select the B channel
(blue) setting.
The adjustment results are registered to memory A.
zThe setting value is displayed during adjustment.
zWhen the R GAIN dial and B GAIN dial are pressed, the setting
values do not change and are only displayed.
R GAIN :
+150
B GAIN :
+150
5.
Press the WHITE BAL B button to turn on its indicator.
Perform step 4 in the same way as with the WHITE BAL A button to
set memory B.
Auto tracking white adjustment (ATW)
You can select the auto tracking white balance (ATW) mode for
automatically tracking the white balance in accordance with the lighting
conditions.
1.
Press the ATW button to turn on its indicator.
ATW mode is enabled.
zIf there is no white on the screen, it may not be possible to
compensate the white balance properly.
Also, it may not be possible to compensate the white balance
properly depending on the lighting conditions.
Setting the black balance
The black balance needs to be adjusted when using a remote camera
for the first time or when a remote camera has not been used for a
prolonged period of time. It also needs to be adjusted when significant
changes have occurred in the ambient temperature or at the change of
the seasons.
When the camera will be used with the same settings and under the
same conditions, the black balance does not need to be adjusted again.
When the black balance is adjusted again, the previous memory data
will be erased and replaced with the new black balance settings.
Automatically adjusting the black balance
1.
Press the ABB button.
The ABB button indicator blinks and the black balance is adjusted by
automatically closing the lens iris.
When adjustment ends successfully, the button indicator turns off
and the adjustment results are registered.
When adjustment was not possible, the ABB button indicator blinks
continuously.
zWhen the black balance is adjusted automatically, the R and
B PED setting values return to “±0”.
Manually adjusting the black balance
(R and B pedestal adjustment)
1.
Connect the video output of the currently selected
remote camera to a waveform monitor.
2.
Press the auto iris button to turn its indicator off.
3.
Turn the IRIS dial to close the lens iris.
4.
Turn the R PED dial to select the R channel (red) setting,
and turn the B PED dial to select the B channel (blue)
setting.
zThe setting value is displayed during adjustment.
zWhen the R PED dial and B PED dial are pressed, the setting
values do not change and are only displayed.
R PED :
+150
B PED :
+150
Making image adjustments for the selected remote camera (continued)