35
CAM INF function
You can display the remote camera setting information acquired by the
unit on the switcher AUX bus output images or multi view images.
Enabling or disabling the CAM INF function
1.
Press the MENU button.
2.
Open SW FUNCTION menu [42].
3.
Turn the F1 dial to display the “8. CAM INF” item.
8.CAM INF
Off
4.
Turn the F2 dial to select “On” or “Off”, and then press
the F2 dial to confirm the selection.
On : Enables the CAM INF view function.
Off : Disables the CAM INF view function.
z Enabling and disabling the CAM INF function can be assigned to a
USER button.
Open USER BUTTON menu [35], display one of the “1. USER1”
to “8. USER8” items, and set “CAMINF”.
z When the USER button with “CAMINF” assigned is pressed, the
operation is as follows.
Button indicator on : Enables the CAM INF function.
Button indicator off : Disables the CAM INF function.
Selecting the remote camera setting information to
superimpose on the images output from the switcher
1.
Press the MENU button.
2.
Open SW FUNCTION menu [42].
3.
Turn the F1 dial to display any of the “9. CAMINF_
FORMAT” to “16. CAMINF_ALARM” items.
9.CAMINF_FORMAT
On
16.CAMINF_ALARM
On
~
9. CAMINF_FORMAT :
1
Video format
(This is left blank when the video
format of the remote camera cannot
be recognized.)
10. CAMINF_CNAME :
2
Remote camera name
11. CAMINF_SCENE :
3
Shooting mode
12. CAMINF_GAIN :
4
Gain value
13. CAMINF_SHUTER :
5
Shutter information (ON/OFF,
shutter value)
14. CAMINF_IRIS :
6
Iris value
15. CAMINF_FILTER :
7
Filter information
16. CAMINF_ALARM :
8
Remote camera alarm information
1080/59i USER
1/100 AUTO
AW-HE120
4.
For each of the items, turn the F2 dial to select “On”
or “Off”, and then press the F2 dial to confirm the
selection.
On : Enables display on the switcher.
Off : Disables display on the switcher.
Setting the functions for when the unit is linked with the switcher (continued)