3-3. Camera Adjustment
n
Before the adjustment, enter the “PAGE 1” of SERVICE
menu, and perform the “RESET”.
3-3-1. Sub-Carrier Frequency Adjustment
Equipment: Frequency counter
To be extended: ES-32 board (for DXC-D35/D35P)
ES-33 board
(for DXC-D35WS/D35WSP)
Test point: TP501 (GND: E501)
/ES-32 board (for DXC-D35/D35P)
/ES-33 board
(for DXC-D35WS/D35WSP)
Adjusting point: SERVICE menu “PAGE 8”
SC FREQ:
Adjust the sub-Carrier Frequency by
UP switch or DOWN switch to
meet the specification.
Specification: 3,579,545 ±10 Hz (for NTSC)
4,433,618 ±10 Hz (for PAL)
3-3-2. INT SC-H Phase Adjustment
n
Stated below is a procedure with the SC-H phase measur-
ing equipment (Tektronix Waveform monitor 1765).
If any other equipment is used, perform adjustment at the
following adjustment point by reading the instruction
manual attached.
Equipment:
Waveform monitor (SC-H Phase mode)
Preparation:
. Put the Tektronix Waveform monitor 1765 to SC-H
mode.
Test point: VIDEO OUT connector
Adjustment Procedure
1. SERVICE menu “PAGE 8”
SC-H
2. Adjust the phase relationship between SC (Burst) and
H beam spot correctly by UP switch or DOWN
switch.
[for NTSC] [for PAL]
n
After this adjustment, set the mode of Tektronix Waveform
monitor 1765 to “WFM” mode.
3-3. Camera Adjustment