Sony DXC-D35 Camcorder User Manual


 
3-18
DXC-D35/D35WS(UC)
DXC-D35P/D35WSP(CE) V1
3-4. Changing the Standard Setting
Values (Video Level)
When changing the setting of black level, flare, gamma,
manual knee and white clip by the user’s desire, perform
the procedures below.
3-4-1. Setting Status before Changing the
Setting.
..
..
. Side Panel
GAIN switch: LOW (0 dB)
OUTPUT/DL/DCC +: CAM/DCC +
WHITE BAL switch: A
ZEBRA switch: OFF
HYPER GAIN switch: OFF
SET UP switch: STD
EZ MODE button: OFF
A.IRIS MODE: STD
ATW button: OFF
..
..
. Front Panel
FILTER control: 1 (3200 K)
SHUTTER switch: OFF
..
..
. Lens
IRIS: M (Manual)
ZOOM: M (Manual)
3-4-2. Changing the Setting Value of Black
Level
Equipment: Waveform monitor
Test point: VIDEO OUT connector
Procedure for changing the setting
1. Set the lens iris to the close position (C).
2. Push the WHT/BLK switch in the “BLK” direction to
make a black balance.
3. SERVICE menu “PAGE 15”
M.BLACK:
4. Set the black level A with the UP or DOWN
switch.
M.BLACK Standard setting value = 2070 (for NTSC)
2075 (for PAL)