Canon VB-C50IR Security Camera User Manual


 
7-24
Restoring the Factory Default Settings
Note
Do not turn the VB-C50i/VB-C50iR power off while the Restoring operation. If you
turn the power off, all settings of the unit restore to the factory default settings.
If you click the “OK” button at this point, it will not possible to abort the process to
restore the default settings. Click the “Cancel” button if you do not wish to restore
the default settings.
4. The VB-C50i/VB-C50iR’s factory default settings are restored.
Settings other than the Administrator password, or network-related settings such as the VB-
C50i/VB-C50iR’s IP address, subnet mask, and default gateway address are returned to factory
default settings.
Note
If the Reset switch is pressed and all factory default settings are restored, the VB-C50i/
VB-C50iR’s network-related settings such as IP address, subnet mask, and default
gateway address are all also returned to the factory default settings, making it
impossible to operate the VB-C50i/VB-C50iR from a PC connected to it. Use
“VBSetup.exe” on the supplied CD-ROM to set an IP address appropriate to the
environment you will be using ( P.2-7).
Resforing the Factory Default Settings from the Reset Switch
If the VB-C50i/VB-C50iR’s IP address or administration password are not known or have been
forgotten, the VB-C50i/VB-C50iR cannot be operated over a network. In this case, press the
Reset switch at the bottom of the unit.
1. Turn off the VB-C50i/VB-C50iR.
See page 2-6 “Turning the Power ON and OFF” for procedures on how to turn OFF and ON
the VB-C50i/VB-C50iR’s power switch.
2. While pressing the Reset switch, turn on the power and keep the Reset switch
pressed from more than 5 seconds.
The Reset switch is located toward the rear on the bottom. Use a thin tipped object such as
the end of a paper clip to press the Reset switch.
All settings in the VB-C50i/VB-C50iR will be returned to the factory default settings.
00008501F162