Canon VB-C50IR Security Camera User Manual


 
2-5
Setting Up
1. Set Up the Camera
a WARNING:
The Wide Converter WL-37 is designed specifically for the VB-C50i and cannot be
used on the VB-C50iR.
Note
The camera may not operate correctly if a wide converter other than the WL-37
is used.
The permissible range of camera installation angles with the wide converter mounted
on the camera is ±15° from the horizontal.
If you use the optional Wide Converter WL-37, set the zoom lens to the wide-angle
end. If you set the zoom lens to the telephoto end, the image resolution will be
affected and the auto focus might have problems.
When the Wide Converter has been set for use in “Camera and Video” ( P.3-9),
the pan and tilt values change for the three functions listed below. If the Wide
Converter is to be used, pan and tilt values must be determined after the use of the
Wide Converter has been set in “Camera and Video”.
• Home position setting ( P.3-8)
• View restrictions ( P.3-9)
• Preset settings ( P.3-12)
When the Wide Converter has been set for use in “Camera and Video” (P. 3-9), the
infrared light cannot be used ( P.4-69).
Wide Converter
Using the Wide Converter (VB-C50i)
The optional Wide Converter WL-37 can be used to provide wide-angle shots (approx. 0.74× the
normal focal distance).
Mount the wide converter correctly so that it is level and fitted securely onto the camera. When
mounted correctly, the wide converter should turn roughly 3 times before stopping.
Setup is now complete.