Bosch Appliances VEZ Security Camera User Manual


 
90 en | Configuring the AutoDome Easy II IP AutoDome Easy II IP
F.01U.164.576 | 2.0 | 2010.03 Installation Manual Bosch Security Systems, Inc.
that, once an IP address is assigned, it is retained each time the
system is rebooted.
IP address
Enter the desired IP address for the AutoDome Easy II IP in this
field. The IP address must be valid for the network.
Subnet mask
Enter the appropriate subnet mask for the selected IP address
here.
Gateway address
If you want the unit to establish a connection to a remote
location in a different subnet, enter the IP address of the
gateway here. Otherwise leave the box blank (0.0.0.0).
12.4 Basic Mode: Encoder Profile
Default profile
You can select a profile for encoding the video signal.
You can use this to adapt the video data transmission to the
operating environment (for example network structure,
bandwidth, data load).
Pre-programmed profiles are available, each giving priority to
different perspectives. When selecting a profile, details are
displayed in the list field.
High resolution 1
High quality, connections with the highest bandwidth,
resolution 704 × 576/480 pixels
High resolution 2
High quality, connections with high bandwidth, resolution
704 × 576/480 pixels
Low bandwidth
High resolution, connections with low bandwidth,
resolution 704 × 576/480 pixels
DSL
DSL connections with 500 kbps, resolution 352 × 288/240
pixels