Pelco DVR5100 Security Camera User Manual


 
C1695M-B (11/08) 13
3. Attach one front-mount rail to one rear-mount rail (refer to Figure 6). Place three 8-32 x 0.375-inch Phillips truss head screws in the
available holes. Leave the screws loose until step 8.
Figure 6. Assembling a Support Rail
4. Repeat step 3 for the other rail set.
5. If installing the unit into a square-hole rack, insert 10 cage nuts into the square-hole rack (refer to Figure 7).
Figure 7. Inserting Cage Nuts
6. Attach one support rail assembly to the equipment rack in the desired location (refer to Figure 8 on page 14).
NOTE: The support rail assemblies are identical and can be used on the right or left side of the rack.
a. Position the ear of the front-mount rail against the front of the equipment rack. Align the top and bottom holes in the ear of the rail
with the threaded holes (or cage nuts) in the rack.
b. Using two 10-32 x 0.5-inch Phillips flat head screws, attach the ear of the rail to the front of the rack. Insert the screws from the
outside of the rack, pointing towards the rear.
c. Adjust the rails to the correct depth of the equipment rack by sliding the rear-mount rail to the back of the equipment rack.
d. Position the ear of the rear-mount rail against the rear exterior of the equipment rack. Align the top and bottom holes in the ear of the
rail with the threaded holes (or cage nuts) in the equipment rack.
(3) SCREWS, 8-32 X 0.375
PHILLIPS TRUSS HEAD
CAGE NUT