58 C1695M-B (11/08)
SEQUENCE MONITOR SETUP
The sequence monitor displays only analog camera inputs (refer to Figure 62). IP Cameras cannot be displayed on the sequence monitor. Refer to
Table AB on page 75 for more information on sequence monitor settings and defaults
Figure 62. Sequence Monitor Screen
To set up the sequence monitor:
1. Global dwell time: Select the time that channel displays are rotated in sequence on the sequence monitor.
2. Interleave video on alarm: When this option is selected, both alarm and normal video can be displayed in an alternating sequence on the
sequence monitor. To disable this feature, clear the check box.
Cameras in the sequence: Select cameras to be included in the sequence list. Select a camera in the “Available cameras” list and click
the “Available cameras” right arrow [or select the “Available cameras “right arrow and press Enter/Shift]. The camera moves to the
“Cameras in the sequence” list. To remove a camera from the sequence, select the camera, and then press the “Available cameras” left
arrow [or select the “Available cameras “left arrow and press Enter/Shift].
NOTE: Cameras may be moved anywhere in the sequence by using the “Cameras in the sequence” up and down arrows. Cameras may
appear more than once in the sequence with an independent dwell time for each appearance.