Alarm Setup Menu Choices:
Menu Description Sub-menu / Description Default
Setting
Exit Saves and exits the menu.
Inputs
Setup
Defines physical inputs or
events and commands that can
be used in a rule. There are
twelve (12) alarm inputs
available.
Inputs 1-7 Defines the type of physical
input.
N.O.: Normally open dry contact.
N.C.: Normally closed dry contact.
N.C.S.: Normally closed supervised
contact.
N.O.S.: Normally open supervised
contact.
N.O.
Low
Pressure
A fixed, physical alarm input
that detects a drop in internal
pressure for the VG4 Pressure
Dome.
Inputs 8-12 Defines input commands that
can be used in a rule.
Command inputs can also be
customized by using non-
assigned keyboard command
numbers.
NONE: No command defined.
Aux On: Responds to a standard or
custom keyboard ON (1-99)
command.
Aux Off: Responds to a standard or
custom keyboard OFF (1-99)
command.
Shot: Responds to a Preset shot or
scene from 1-99. (200 Series 1-64).
AutoTrack: Triggers an alarm when
set to ON. (Available with 500i Series
only).
Motion Detection: Triggers an alarm
when set to ON. (Available with 500i
Series only).
NONE
NOTICE! Alarm inputs 1 and 2 provide tamper detection, if programmed as supervised, for
breaks or shorts in an alarm circuit. See the AutoDome Modular Camera System Installation
Manual for wiring instructions.