Bosch Appliances VG4-200 Security Camera User Manual


 
VG4 Modular Camera System Configuring the IP AutoDome | en 97
Bosch Security Systems, Inc. User’s Manual F.01U.133.268 | 6.0 | 2010.03
Deactivating Storage Media
You can deactivate any storage medium from the Managed storage media list. It is then no
longer used for recordings.
1. Click a storage medium in the Managed storage media list to select it.
2. Click the Remove button below the list. The storage medium is deactivated and removed
from the list.
10.40 Advanced Mode: Recording Profiles
You can define up to ten different recording profiles. You will then use these recording
profiles in the recording scheduler, where they are linked with the individual days and times
(see Section 10.42 Advanced Mode: Recording Scheduler, page 97).
1. Click one of the tabs to edit the corresponding profile.
2. If necessary, click the Default button to return all settings to their default values.
3. Click the Copy Settings button if you want to copy the currently visible settings to other
profiles. A new window will open and you can select the profiles in which you want to
copy the settings.
4. For each profile, click the Set button to save the settings in the unit.
Stream profile settings
You can select the profile setting that is to be used for each data stream in the event of
recordings. This selection is independent of the selection for live data stream transmission
(see Section 10.17 Advanced Mode: Encoder Streams, page 80).
The properties of the profiles are defined on the Encoder Profile page (see
Section 10.16 Advanced Mode: Encoder Profile, page 78).
Recording includes
You can specify whether, in addition to video data, audio data and metadata (for example
alarms, VCA data and serial data) should also be recorded. Including metadata could make
subsequent searches of recordings easier but it requires additional memory capacity.
Standard recording
Here you can select the mode for standard recordings.
If you select Continuous, the recording proceeds continuously. If the maximum memory
capacity is reached, older recordings will automatically be overwritten. If you select the Pre-
alarm option, recording will only take place in the pre-alarm time, during the alarm and during
the set post-alarm time.
If you select Off, no automatic recording takes place.
NOTICE!
You can change or add to the recording profile description on the tabs on the Recording
Scheduler page (see Section Time periods, page 98).
CAUTION!
Without metadata, it is not possible to include video content analysis in recordings.
CAUTION!
You can specify limitations for overwriting older recordings in Continuous mode by
configuring the retention time (see Section 10.41 Advanced Mode: Retention Time, page 97).