82 en | Configuring the IP AutoDome VG4 Modular Camera System
F.01U.133.268 | 6.0 | 2010.03 User’s Manual Bosch Security Systems, Inc.
Sync. Mode
Selects the synchronization method for the camera.
– Line Lock: synchronizes the camera to AC power and eliminates picture roll in multi-
camera systems.
– Internal (default): locks the power into the internal crystal.
Line Lock Delay
Adjusts the vertical line lock phase delay from 0° to 359°.
To set the Line Lock Delay, type a value, in degrees, between 0 (default) and 359 inclusive.
This setting optimizes the Line Lock mode to eliminate picture roll in multiphase power
applications.
10.21 Camera Settings Group 2
Shutter Mode
– Off: turns the Auto SensUP Off.
– Auto SensUP (default): increases camera sensitivity by increasing the integration time on
the CCD. This is accomplished by integrating the signal from a number of consecutive
video frames to reduce signal noise.
Shutter
Adjusts the electronic shutter speed (AES). Controls the time period for which light is
gathered by the collecting device. The default setting is 1/60 second.
Auto SensUp Maximum
Sets the Auto SensUp minimum value for the AutoDome. The Auto SensUp Min. value is the
factor by which the sensitivity of the camera is increased. The default setting is 15x.
Night Mode (Day/Night models only)
Adjusts the filter operation of the camera.
– Off: activates day mode (color) and does not allow the camera to switch to the night
mode.
– On: activates night mode to enhance lighting in low light scenes.
– Auto (default): allows the camera to set the Night Mode based on the light conditions of
the scene.
Night Mode Threshold
Adjusts the level of light at which the camera automatically switches out of Night Mode (B/W)
operation. 10 is earlier, 55 is later.
Night Mode Color
Switches an Auto IR filter in monochrome operation.
– On: color processing remains in effect while the camera is in night mode.