Bosch Appliances VG4-200 Security Camera User Manual


 
38 en | Alternative Control Protocols VG4 Modular Camera System
F.01U.133.268 | 6.0 | 2010.03 User’s Manual Bosch Security Systems, Inc.
4.2.3 Pelco Keyboard Commands
4.2.4 Special Preset Commands
Some Pelco mode preset commands have a special meaning and override the normal Pelco
preset function as follows:
Keyboard Command User Action Description
0-Pattern Press Initiates recording continuous playback based upon
current Recording setting (A or B) in the Setup Menu.
Press and hold Initiates recording based upon current Recording
setting (A or B) in the Setup Menu. Press ACK to end
recording.
1-Pattern Press Initiate Recording A continuous playback.
Press and hold Initiate Recording A. Press ACK to end recording.
2-Pattern Press Initiate Recording B continuous playback.
Press and hold Initiate Recording B. Press ACK to end recording.
3-Pattern Press Initiate the AutoDome standard preset tour (Tour 1).
4-Pattern Press Initiate the AutoDome custom preset tour (Tour 2).
1 – Aux On / Aux Off Press Activates / deactivates alarm output 1.
2 – Aux On / Aux Off Press Activates / deactivates alarm output 2.
3 – Aux On / Aux Off Press Activates / deactivates alarm output 3.
4 – Aux On / Aux Off Press Activates / deactivates alarm relay.
91 – Aux On Press Activate Zone Scan (display zone titles).
92 – Aux On Press Deactivate Zone Scan (re-move zone titles)
Preset Command Description
33-PRESET Pans the AutoDome 180° (Flip).
34-PRESET Goes to Zero Pan (original home position).
80-PRESET Toggles the Synchronization Mode between Line Lock and Internal
(Pelco Frame Scan). This command is available if commands are
unlocked using the Main menu.
81-PRESET Initiates Preset Tour 1.
82-PRESET Initiates Preset Tour 2.
92-PRESET Sets the Left pan limit for an AutoScan with Limit Stops enabled.
93-PRESET Sets the Right pan limit for an AutoScan with Limit Stops enabled.
94-PRESET Initiates a Preset Tour.
95-PRESET Enables or disables Limit Stops in the Setup Menu for AutoScan.
Invokes the Pelco main Setup Menu when pressed for 2 seconds.
96-PRESET Stops a scan.
97-PRESET Initiates FastAddress (Pelco Random Scan).
98-PRESET Toggles the Synch. Mode between Line Lock and Internal (Pelco Frame
Scan). This command is available only for two (2) minutes after the
power is applied and then reverts to normal preset functionality.
99-PRESET Starts an AutoScan
NOTICE! Some Pelco controllers do not support all the preset command numbers. Consult
the specific Pelco controller's documentation for supported preset commands.