VG4 Modular Camera System On-Screen Display Menu Navigation | en 29
Bosch Security Systems, Inc. User’s Manual F.01U.133.268 | 6.0 | 2010.03
2.11.1 Alarm Status Submenu
This menu displays the status of the alarm inputs, alarm outputs and the pressure alarm.
Menu items marked with the ‡ symbol are available only with VG4 Pressure Domes.
VG4 Pressure Dome Alarm
The OSD displays a blinking low pressure alarm (*** LOW PRESSURE ***) when the internal
pressure of a VG4 Pressure Dome falls below the recommended level. Press OFF-65-ENTER
on the keyboard to acknowledge the alarm. The AutoDome, then, replaces the blinking alarm
message with a static “LP.” The “LP” remains on the OSD until the internal pressure of the
AutoDome is raised above the recommended level.
Alarm Status
Exit...
Alarm Input 1 High
Alarm Input 2 High
Alarm Input 3 Open
Alarm Input 4 Open
Alarm Input 5 Open
Alarm Input 6 Open
Alarm Input 7 Open
Pressure‡ OK
Alarm Output 1 Open
Focus / Iris: Save and Exit
Menu Description Options
Exit Saves and exits the menu.
Alarm Input 1...7 Displays the status of alarm
inputs 1 through 7.
High
Low
Open (Normally Open)
Closed (Normally Closed)
Pressure Displays the status of the
Pressure alarm
OK: The internal pressure inside
the AutoDome is at or above the
recommended level.
Low: The internal pressure
inside the AutoDome is below
the recommended level. Refer to
the AutoDome Modular Camera
System Installation Manual for
instructions on recharging the
pressure.
Alarm Output Displays the status of the alarm
output.