Bosch Appliances VG4-200 Security Camera User Manual


 
50 en | Advanced Features VG4 Modular Camera System
F.01U.133.268 | 6.0 | 2010.03 User’s Manual Bosch Security Systems, Inc.
13. Select Shot 1 from the Output Options drop-down list.
This option instructs the AutoDome to move to pre-position shot 1 when Input 1 is true.
Figure 7.4 Alarm Rule 1 Configuration
14. Move the Output slider bar to Output 2.
15. Select Tracking from the Output Option drop-down list.
This option instructs the AutoDome to activate the AutoTrack feature after the input
alarm is triggered and after the AutoDome moves to pre-position 1.
16. Select 5 sec from the Output Period drop-down list.
This option instructs the AutoDome to turn off the AutoTrack feature after five seconds
from when the tracked object is out of view.
7.2 AutoTrack Operation (500i Series Only)
The 500i Series AutoDome features enhanced AutoTrack software with more versatility and
smoother object tracking. AutoTrack is now able to continuously follow an individual even if
the person passes behind a Privacy Mask. When used with Virtual Mask, it is able to ignore
predefined areas of background motion.
You can manually start AutoTrack or program the VG4 500i Series AutoDome to automatically
turn on AutoTrack.
Manual
Enter the keyboard command ON-78-ENTER.
In Pelco Mode, open the Main menu, select the Advanced menu, and then select
AutoTrack On.
Automatic
During a pre-position tour.
–During AutoPan.
AutoDome activates AutoTrack after a period of Inactivity (Return to Scene 1 or
Return to Previous Aux), if AutoTrack is programmed for these activities.
NOTICE! For proper operation AutoTrack requires that the camera height be set in the
software. Open the Bosch Main menu, select the Advanced menu and select Camera Height to
enter the height.