Bosch Appliances VG4-200 Security Camera User Manual


 
90 en | Configuring the IP AutoDome VG4 Modular Camera System
F.01U.133.268 | 6.0 | 2010.03 User’s Manual Bosch Security Systems, Inc.
Basic Alarm Rule Example
The following is an example for setting up a basic door alarm rule to:
1. Flash an OSD message (***ALARM 1***) on the display when the alarm is triggered.
2. Move the AutoDome camera to a saved position (for this example use Shot 7).
3. Transmit a Bilinx signal over the coax cable to the headend system, such as an Allegiant,
to trigger an alarm response.
The sequence to program the above alarm rule is as follows:
1. Open the IP AutoDome LIVEPAGE, then click the Settings tab.
2. Click the Camera Settings link, click Alarm, expand Input Options, and click Input
Options 1. The IP AutoDome displays the input Options 1 screen.
a. Ensure the drop-down list for Type is set to Alarm Input 1.
b. Click the drop-down list for Alarm Input and set to N.O. (normally open). This setting
is the default for Input 1. Additional inputs include:
c. N.C. (Normally Closed, dry contact)
d. N.C.S. (Normally Closed Supervised contact, available only for alarm inputs 1 and 2)
e. N.C.O. (Normally Open Supervised contact, available only for alarm inputs 1 and 2)
Figure 10.2 Input Options Settings Example