VG4 Modular Camera System Configuring the IP AutoDome | en 93
Bosch Security Systems, Inc. User’s Manual F.01U.133.268 | 6.0 | 2010.03
8. Within the Output Options, do the following:
a. Move the slider bar or type the number 1 in the Output # field.
b. Click the Output Option drop-down list and select 5: OSD.
Figure 10.7 Alarm Rule 1 Example
9. Within the Output Options, do the following:
a. Move the slider bar or type the number 3 in the Output # field.
b. Click the Output Option drop-down list and select 7: Transmit.
c. Click the Output Period drop-down list and select 3 sec.
d. Click the Yes radio button to enable Alarm Rule 1.
Figure 10.8 Alarm Rule 1 Example