36 en | Alternative Control Protocols VG4 Modular Camera System
F.01U.133.268 | 6.0 | 2010.03 User’s Manual Bosch Security Systems, Inc.
6. The on-screen display menu confirms that the VG4 AutoDome stored the FastAddress
and then returns to the Main menu with the new Fast Address displayed. Move the
joystick to highlight EXIT, and then press FOCUS or IRIS to exit the menus.
4.1.2 Using a Pelco Controller
This section provides instructions to set a FastAddress with a Pelco keyboard or controller.
– An AutoDome with an address set to 0 responds to commands set to any address.
– Pelco-P protocol must use addresses 1 to 32.
– Pelco-D protocol must use addresses 1 to 254.
Setting FastAddress with a Pelco Keyboard
1. Press and hold 95-PRESET for two seconds to open the Pelco Setup menu.
2. Move the joystick to select the Command Lock menu.
3. Press the FOCUS or the IRIS button to turn Command Lock to OFF.
4. Move to the FastAddress menu and press the FOCUS or the IRIS button to open the
menu.
5. Use the joystick to enter the unique identifier for the VG4 AutoDome.
– Move the joystick up or down to select the number.
– Move the joystick right to move to the next number position.
6. Move the joystick right to select Continue. Then, press the FOCUS or the IRIS button.
7. Use the keyboard to enter the FastAddress number. Then, press the Camera button.
Note: You must first clear an assigned FastAddress number to use the number for a
different VG4 AutoDome.
8. Move the joystick down then back up to set the FastAddress number.
9. Press the FOCUS or the IRIS button to store the FastAddress number.
The on-screen display menu confirms that the VG4 AutoDome stored the FastAddress
number.
New Fast Address Saved
Setup Menu
Exit...
Command Lock: OFF
Bosch Menu
Camera Setup
PTZ Setup
Edit Password
*FastAddress: 3
Software Version
Ack and Reset Alarms
Restore All Settings
* = Factory Setting
Focus / Iris: Select
NOTICE! A previously configured AutoDome with an address above 32 (Pelco-P upper limit) or
254 (Pelco-D upper limit) can be used without readdressing the unit. However, no two (2)
addresses can be the same. For example:
Pelco-P addresses above 32 are repeated in multiples of 32 (1, 33, 65, 97 are the same).
Pelco-D addresses above 254 are repeated in multiples of 254 (1, 255, 509, 763 are the
same).