Enterasys Networks X009-U Camera Accessories User Manual


 
Features
Matrix X4-C Chassis Installation Guide 1-5
5. InsertthestandbyCMintothesystemandwaituntilitisfullysynchronizedwiththeactive
CMbeforeremovingtheactiveCM.DonotphysicallyremovetheactiveCMduringthe
synchronizationprocess.Thefollowingmessagewillappearonyourconsolescreen:
MXS Standby: Synchronization monitoring system
MXS CM Standby: SYNCING DATA. Do not remove the Active CM
configuration data 124 MB Copying 10.4%(2006 KBPS)00m56s remain
high-availability data256 MB Copy-Pending
6. Tomanuallycheckthestateofthesynchronizationprocess,entertheshowsystemhigh
availabilitycommandwhichwilldisplaythefollowingoutput:
matrix-x(switch-su)-> show system high-availability
SYSTEM HIGH-AVAILABILITY INFORMATION
------------------------------------
System Coldstart: Wed Mar 9 12:28:24 2005
Current Time: Wed Mar 9 18:36:06 2005
Total System Uptime: 0d06h07m42s
HA-Channel: Primary - Online
Configuration: Non-Redundant (Coldstart after Reboot)
Total Failovers Since Coldstart: 0
Early Repetitive Failure Protection: 10m00s, 00n45s remain
Active Module: CM1
Standby Module: Synchronizing
CONTROL MODULE INFORMATION
--------------------------------
CM1 In-Service Active Uptime:0d00h54m08s 1.3.2.N
CM2 In-Service Standby
Replication Status:
--------------------------------
configuration data 124 MB Copying 10.4%(2006 KBPS)00m56s remain
high-availability data 256 MB Copy-Pending
The following conditions are preventing a Hot-Redundant configuration:
--------------------------------
* Hot-Failover is disabled
* Early repetitive failure protection timer has not expired
* Synchronizing configuration data
* Synchronizing high-availability data
AfterafewminutesthismessagewillappearontheStandbyControlModuleindicating
synchronizationiscomplete:
MXS Standby: Availability monitor Wed Jan 10 10:26:00 2007
MXS CM Hot In-Service Standby: Waiting for failover
Total System Uptime: 23d14h08m12s