Enterasys Networks X009-U Camera Accessories User Manual


 
Power Supply Requirements, Specifications, and Twist Lock Options
A-2 Specifications and Regulatory Compliance
Power Supply Requirements, Specifications, and Twist Lock Options
TherequirementsforMatrixXRouterACpowersupplymodulesareasfollows:
ThepowerspecificationsforMatrixX Routermodules,showninTable A3,andredundancy
configurationtables,showninTable A4 andTable A5,areusefulguides forpowerbudget
planning.Toestimateapowerbudget,simplytotal
thewattageofeachinstalledmodule,making
surethecombinedwattageconsumedisnogreaterthan100%oftheoutputofthepower
supply(ies).
Fan Tray
Dimensions 4.13 cm H x 12.7 cm W x 56.52 cm D
1.625 in. H x 5.0 in. W x 22.25 in. D
Weight 3.31 kg (7.3 lb)
MTBF (Predicted) 381,219 hours
Environmental
Operating Temperature 5°C to 40°C (41°F to 104 °F)
Storage Temperature -30°C to 73°C (-22°F to 164°F)
Operating Relative Humidity 5% to 95% (non-condensing)
Table A-1 Matrix X4-C Specifications (continued)
Item Specification
Table A-2 AC Power Supply Requirements
Item Specification
Input Frequency 50 to 60 Hz
Input (Voltage/Current) 100 to 125 Vac: 16 A
200 to 240 Vac: 8 A
Output Power 1160/1500 Watts
Table A-3 Module Power Specifications
Module
@ 110 Vac / 220 Vac
Power (Watts) Thermal Output (BTU/HR)
CM 97 Watts 331.1 BTU/HR
Fan tray 85 Watts 290.1 BTU/HR
X4-FM 30 Watts 102.4 BTU/HR
X8-FM 62 Watts 211.6 BTU/HR
X16-FM 98 Watts 334.5 BTU/HR
X-G32-00 155 Watts 520.0 BTU/HR
X-GT16-00 105 Watts 358.3 BTU/HR