Panasonic AG-3DP1G Camcorder User Manual


 
122
Chapter 8 Connecting to External Devices
Connecting the AG-EC4G Extension Control Unit
Some functions can be remote controlled when the AG-
EC4G extension control unit (optional accessory) is
connected to the camera.
When the AG-EC4G is connected, the camera
automatically enters remote control mode after the power
switches of both the camera and the AG-EC4G are turned
ON.
The remote control mode is released when AG-EC4G is
removed or the power for the AG-EC4G is turned OFF.
Switch/button operations in remote control
mode
The following switches and buttons on the camera do not
work in remote control mode.
SHUTTER switch
MENU button
JOG dial button
GAIN selector switch
OUTPUT/AUTO KNEE selector switch
WHITE BAL switch
USER MAIN button
USER 1 button
USER 2 button
OUTPUT CHARACTER switch
REMOTE connector
AG-EC4G
NOTE
• Be sure to turn the POWER switches on the camera and
the AG-EC4G off before connecting or disconnecting the
controller cable.
• Use only designated cables or designated option cables to
connect the AG-EC4G. Use of other cables could result in
equipment damage.
For details on the current provided by the REMOTE connector,
refer to page 138.
• Data for the operations performed by the AG-EC4G are
generally stored in the camera.
• Setting the DATA SAVE switch on the AG-EC4G to OFF resets
the following values to the values before connecting the AG-
EC4G.
- Synchro scan value
- Master Pedestal value
- GAIN values (R/B)
- Pedestal values (R/G/B)
- GAIN value (at LOW position)
Adjusting the Convergence Point
The convergence point can be adjusted, using the buttons
on the AG-EC4G.
c
b
a
a USER buttons (USER MAIN/USER1)
b RECORDER switch
c tREW, yFF, gSTOP and qPLAY buttons
1
In the SW MODE screen, assign R CONV to
the USER MAIN or USER1 button.
2
Press the USER button to which R CONV has
been assigned on the AG-EC4G.
3
Set the RECORDER switch to ENABLE.
4
Adjust the convergence, using the gSTOP
and qPLAY buttons for coarse adjustment
and the tREW and yFF buttons for fine
adjustment.
gSTOP, tREW: to adjust the convergence point
nearer
qPLA
Y, yFF: to adjust the convergence point
farther
NOTE