![](http://pdfasset.owneriq.net/f/e8/fe8bbf29-dc9c-45c0-b18b-99a4b4c984aa/fe8bbf29-dc9c-45c0-b18b-99a4b4c984aa-bg47.png)
71
Chapter 4 Adjustments and Settings for Recording
• REC WARNING
This is displayed during a recording error. Do the
recording over. If this does not solve the problem,
consult your supplier.
• CARD
ERR L (R) (L/R):
This indicates trouble with the P2 card(s)
inserted into the card slot(s).
•
Turn the power off if the warning continues.
• If the warning persists after rerecording, replace
the card with another card.
• IRREGULAR
FRM SIG:
The reference signal, such as the GENLOCK
input, is distorted.
• L/R
DURATION NG:
The duration of the recorded clip is different
between the L and R P2 cards.
• O
VER MAX# CLIPS: The limit for the number of clips
that can be recorded to one P2 card has
been reached.
• PULL
DOWN ERROR: Video pull-down sequence
error in a mode such as 24P (25P)
•
REC RAM OVERFLOW: Overflow of recording memory
• ERROR
:
Other causes
• RUN DOWN CARD L (R) (L/R)
This message indicates that a P2 card has been
overwritten the maximum number of times and that
normal recording cannot be guaranteed if operation
continues.
It is best to replace such P2 cards with a new card.
•
SYSTEM ERROR
This message indicates that a system error has
occurred. This type of error can often be corrected by
turning off the power and turning it back on again.
• CAM
MICON ERROR: The microprocessor in the
camera is not responding.
• P
2 CONTROL ERROR: A P2 control error has
occurred.
• P
2 MICON ERROR: The P2 microprocessor does not
respond
• P
2 MICON LINK ERROR: A connection error between
P2 microprocessors has occurred.
•
THUMBNAIL OPEN
This message is displayed in the viewfinder during
thumbnail operations.
• TURN POWER OFF
This message indicates that an abnormal event has
occurred, for example, that a card was removed during
access or that a system mode change was made.
Turn the power off and then turn it back on again.
•
WARNING
These messages are displayed when an error related to
the camera block is detected.
• FOCUS
NG L(R)(L/R): Focus error
• ZOOM
NG L(R)(L/R): Zoom error
• IRIS
NG L(R)(L/R): Iris error
• ND
FILTER NG L(R)(L/R): ND filter error
• CONV
. NG L(R)(L/R): Convergence error
• SUB
LENS NG L(R)(L/R): Sub-lens error
• VERSION MISMATCH
PLEASE UPDATE
This message is displayed if a version mismatch has
occurred.
Perform card updating.
•
WIRELESS RF
This message indicates that reception from the wireless
receiver is poor.
Camera status display
• ABB
ABB indicator
•
AUTO KNEE (ON/OFF)
Displayed when changing the AUTO KNEE switch
position.
• AWB
AWB indicator
•
AWB P3.2K/AWB P5.6K
Displays the color temperature assigned to PRST when
the WHITE BAL switch is set to PRST. Also displayed
when AWB is performed in the PRST position.
•
GAIN dB
Displayed when GAIN is switched.
•
SHUTTER
(OFF)
Displayed when the shutter speed is changed.
3D status display
• 3D ASSIST
• ALERT(ON/OFF): Status indication of the 3D ASSIST
ALERT function
• CONV.(ON/OFF): Status indication of the 3D ASSIST
CONV. function
•
3D ASSIST ACTIVE
Displayed when the ZEBRA button is pressed while the
3D assist function is active.
• 3D MODE
• NEAR: Displayed when the 3D MODE selector switch
position is changed to NEAR
• NORMAL: Displayed when the 3D MODE selector
switch position is changed to NORMAL.
• EXTRA
ZOOM: Displayed when the 3D MODE
selector switch position is changed to EXTRA.