Chapter 4 Adjustments and Settings for Recording
• REC WARNING
This is displayed during a recording error. Do the
recording over. If this does not solve the problem,
consult your supplier.
CARD
ERR L (R) (L/R):
This indicates trouble with the P2 card(s)
inserted into the card slot(s).
Turn the power off if the warning continues.
If the warning persists after rerecording, replace
the card with another card.
IRREGULAR
FRM SIG:
The reference signal, such as the GENLOCK
input, is distorted.
L/R
DURATION NG:
The duration of the recorded clip is different
between the L and R P2 cards.
O
VER MAX# CLIPS: The limit for the number of clips
that can be recorded to one P2 card has
been reached.
PULL
DOWN ERROR: Video pull-down sequence
error in a mode such as 24P (25P)
REC RAM OVERFLOW: Overflow of recording memory
ERROR
:
Other causes
• RUN DOWN CARD L (R) (L/R)
This message indicates that a P2 card has been
overwritten the maximum number of times and that
normal recording cannot be guaranteed if operation
continues.
It is best to replace such P2 cards with a new card.
SYSTEM ERROR
This message indicates that a system error has
occurred. This type of error can often be corrected by
turning off the power and turning it back on again.
CAM
MICON ERROR: The microprocessor in the
camera is not responding.
P
2 CONTROL ERROR: A P2 control error has
occurred.
P
2 MICON ERROR: The P2 microprocessor does not
respond
P
2 MICON LINK ERROR: A connection error between
P2 microprocessors has occurred.
THUMBNAIL OPEN
This message is displayed in the viewfinder during
thumbnail operations.
• TURN POWER OFF
This message indicates that an abnormal event has
occurred, for example, that a card was removed during
access or that a system mode change was made.
Turn the power off and then turn it back on again.
WARNING
These messages are displayed when an error related to
the camera block is detected.
FOCUS
NG L(R)(L/R): Focus error
ZOOM
NG L(R)(L/R): Zoom error
IRIS
NG L(R)(L/R): Iris error
ND
FILTER NG L(R)(L/R): ND filter error
CONV
. NG L(R)(L/R): Convergence error
SUB
LENS NG L(R)(L/R): Sub-lens error
• VERSION MISMATCH
PLEASE UPDATE
This message is displayed if a version mismatch has
occurred.
Perform card updating.
WIRELESS RF
This message indicates that reception from the wireless
receiver is poor.
Camera status display
• ABB
ABB indicator
AUTO KNEE (ON/OFF)
Displayed when changing the AUTO KNEE switch
position.
• AWB
AWB indicator
AWB P3.2K/AWB P5.6K
Displays the color temperature assigned to PRST when
the WHITE BAL switch is set to PRST. Also displayed
when AWB is performed in the PRST position.
GAIN dB
Displayed when GAIN is switched.
SHUTTER 
(OFF)
Displayed when the shutter speed is changed.
3D status display
• 3D ASSIST
ALERT(ON/OFF): Status indication of the 3D ASSIST
ALERT function
CONV.(ON/OFF): Status indication of the 3D ASSIST
CONV. function
3D ASSIST ACTIVE
Displayed when the ZEBRA button is pressed while the
3D assist function is active.
• 3D MODE
NEAR: Displayed when the 3D MODE selector switch
position is changed to NEAR
NORMAL: Displayed when the 3D MODE selector
switch position is changed to NORMAL.
EXTRA
ZOOM: Displayed when the 3D MODE
selector switch position is changed to EXTRA.