Chapter 3 Basic Adjustments and Settings
1) The control in synchronization with recording is valid only when the SRW-
1 is directly docked on the camera or is optically connected to the camera
via the CA-F101. The RUN indicator of the camera then lights.
If the internal temperature rises so high that the
TEMPERATURE CARE message is displayed, the fan
rotation speed will automatically increase to lower the
temperature.
If the internal temperature rises so high that the TEMP
WARNING/FAN MAX message is displayed, the Fan
Operation mode setting is automatically changed to
MAX. After the temperature is sufficiently lowered and
the message disappears, manually restore the original
mode.
When the video format is set to 50P, S50P, S59.94P, or
S60P, the fans are controlled as in AUTO1 mode even if
AUTO2 or MIN mode has been selected, so that any rise
in internal temperature due to an increase in power
consumption will be suppressed. The control function in
synchronization with recording does not operate in this
condition.
To change Fan Operation mode using the menu
You can also change Fan Operation mode (FAN MODE)
by using the <OTHERS 1> page on the USER
(MAINTENANCE) menu (page 88).
3-2-10 ON/OFF of the Character
Indication
Superimposition of character data onto camera images can
be activated or deactivated by output destination.
Character indication setting page
VF1
Viewfinder connected via the VF1 connector (default: ON)
VF2
Viewfinder connected via the VF2 connector (default: ON)
MON
Monitors connected via the MONITOR OUT HD SDI
connectors (default: ON)
VBS
Monitors connected via the TEST OUT and REMOTE
connectors (default: ON)
3-2-11 Allocation of Functions to
the Assignable Buttons and Switch
Various functions can be allocated to assignable buttons 1
to 3 and assignable switch 4 (the upper position of the 4/
AUTO BLK BAL switch) that are located on the side of the
camera and on the assistant panel.
At shipment, no function is allocated to these buttons.
Functions that can be allocated to assignable
buttons 1 to 3
Setting Operation of the fans
AUTO1 (default) The fans are automatically controlled
according to the internal temperature.
During recording, the fans are
controlled for a quiet condition.
1)
Normally use this mode.
AUTO2 The fans are normally controlled as
those in MIN mode and for a quieter
condition during recording.
1)
Note that
recording time must be limited to a short
duration. Use this mode only under
ordinary ambient temperature.
MIN The quietest fan operation is maintained
without synchronization with recording.
This is the best mode if recording must
be made for more than 30 minutes in a
quiet condition such as a concert hall.
Use this mode only under ordinary
ambient temperature.
MAX The fans rotate at the maximum speed
to lower the internal temperature.
Notes
Menu
indication
Function
ND Selection of the ND filter
REC REVIEW With REC REVIEW set to NORM on the
SRW-1, the last part of the recorded tape
is normally rewound for 3 seconds
(maximum: 10 seconds) then played
back.
With REC REVIEW set to ALL on the
SRW-1, the tape is rewound to the
recording start position then played back.
PB(VF) The video signals being played back on
the SRW-1 are output to the viewfinder.
VF MLUT ON/OFF of the monitor LUT for the
viewfinder
MONI MLUT ON/OFF of the the monitor LUT for
external monitors
FAN MODE Switching of Fan Operation mode
VF1:ON VF2:ON