Sony F35 Camcorder User Manual


 
45
Setting the Camera Outputs
Chapter 3 Basic Adjustments and Settings
Timing of the pulse signal
Example 1: SHUTTER OFF
Example 2: SHUTTER ON, shutter angle 180º
RM [SIG]
The video signals to be output to equipment connected via
the REMOTE connector can be selected.
VF [SIG]
This column is for display only and cannot be changed.
[SRC] and [MLUT] columns
They show the output mode and MLUT ON/OFF settings
set on the <PB/MONI LUT> page.
3-5-2 Setting the Monitor Picture
Using the <PB/MONI LUT> page of the USER
(OPERATION) menu displayed on the viewfinder screen,
you can set the LUT (look-up table) for monitor pictures
and select the playback-picture monitor mode.
About the MLUT (monitor look-up table)
S-LOG gamma pictures are usually of low contrast and
may not be ideal for checking video images on the spot.
The MLUT function enables you to obtain images suited
to monitoring by converting the picture contrast for output
signals from the VF, MONITOR OUT HD SDI, and TEST
OUT connectors. This conversion has no effect on images
at the main line output of the camera.
Use MLUT for recording intended for postproduction
editing, using a S-LOG gamma without adjustments,.
<PB/MONI LUT> page
MLUT/PBMIX
Selecting MLUT activates the monitor LUT function for
monitor pictures. The monitor LUT appropriate for
checking images can be applied to the video signals (VF,
MONI, and VBS) selected for output on the <MONITOR
OUTPUT> page.
Selecting PBMIX permits you to compare the playback
picture and the camera image by displaying them on the
same screen. How this is to be displayed can be set on the
<PB MIX SETTING> page of the USER (OPERATION)
menu (see page 47).
MLUT cannot be selected on the MLUT/PBMIX line if no
MLUT is selected in advance on the MLUT SEL line.
To apply monitor LUT to the monitor
picture
When SPECIAL or USER is selected for the gamma table
(see page 58), the monitor LUT appropriate for checking
images
can be applied to the output video signals (VF,
MONI, and VBS) selected for output on the <MONITOR
OUTPUT> page by selecting MLUT on the MLUT/
PBMIX line.
This setting is effective when S-LOG gamma is applied to
the video output signals for recording intended for post-
production editing.
Setting Signal
VBS The VBS signals are output. (Default)
VF2 The HD-Y signals are output.
REFTHRU The reference signal that is input to the
GENLOCK IN connector is output as-is.
FRAME A pulse is output per frame (in a case of
1 FPS, one pulse per second).
Setting Signal
VBS The VBS signals are output. (Default)
VF2 The HD-Y signals are output.
CCD exposure
Frame pulse
1 frame
ExposureExposure
CCD exposure
Frame pulse
1 frame
Exposure
Exposure
Setting Function
MLUT The MLUT appropriate for checking images
selected at MLUT SEL becomes valid.
PBMIX Both the playback picture and the camera
image are obtained on all the monitor displays.
OFF The same image as that at the main line
output of the camera is obtained on all the
monitor displays. (Default)
Note
<PB/MONI LUT> U07
MLUT/PBMIX:
B
OFF
MLUT SEL: 709(800%)
[CAM/PB] [MLUT]
VF : AUTO OFF
MONI : AUTO OFF
VBS : AUTO OFF
MLUT MARK: OFF LEVEL: 3
H POS: 99 Y POS: 99