ARRI 16SR3 Film Camera User Manual


 
49
Adjustment Normal 16/Super 16
8. Adjustment Normal 16 /Super 16
The centre of the image format is 1 mm different for the
Super 16 (12.4 x 7.5 mm) than for Normal 16 (10.3 x
7.5 mm). In changing the image format, the lens mount
and the viewfinder on the camera must be adjusted 1
mm to centre it. The opening of the Universal film gate
is altered merely by addition or removal of a rail. For
both formats different fibre optic viewing screens must
be used.
Also on the bridge plate, the leightweight support and
the video optic the adjustments for Normal 16 or Super
16 must be carried out.
Adjusting on the Camera
Special Tool Kit
Included with camera
Altering the Lens Alignment
Check Flange focal distance. See Chapter 13
Standard: 52.000 0.010 mm
HS: 51.970 0.010 mm
Remove the 6 cylinder head screws .
Turn the lens mount 180°. The desired format (N16 or
S16) must be top right.
Ensure that the adjustment shims are not bent,
dirtied or twisted during insertion.
lock ring stop
lens locating
pin
cylinder head
screws
lens lock-ring
handle