90
Maintenance
Necessary Special Tools
Depth gauge for PL-mount
or
Depth gauge A 16 SR-18
Depth gauge cylinder A 16 SR-19
Depth gauge base A 16 SR-20
Depth gauge plate A 16 SR-21
Checking the Flange Focal Distance
• Adjust the depth gauge with the gauge cylinder on
the gauge base to „0“.
• Turn the mirror shutter downwards with the inching
knob.
• Lay the gauge plate on the film gate and check the
flange focal distance with the gauge.
• Standard camera: 52,000 mm -0,010 mm
HS camera: 51,970 mm -0,010 mm
Adjusting the Flange Focal Distance
The flange focal distance can be set with the adjustment
shims which sit between the camera housing and the PL-
mount.
• Check the flange focal distance (see above).
• If appropriate remove the compensation adapter.
• Unscrew the 6 cylinder head screws.
• Remove the PL-mount.
• Exchange the adjustment shims, ensuring that they do
not get bent, dirtied or twisted in the process.
• Replace the PL-mount, ensuring that the marking for
the chosen format is in the upper right-hand corner.
• Screw in the 6 cylinder head screws.
Pull the 6 cylinder head screws tight before
checking the flange focal distance as other-
wise a false reading will be attained.
• Check the flange focal distance (see above).