ARRI 16SR3 Film Camera User Manual


 
61
Display and Operating Elements
The sliding switch is at PS/CCU. The programmed speed is 23,455 fps.
The third position after the comma for the speed setting (1/1000 fps) is
displayed in the upper display line.
There is no external synchronization unit, speed unit or remote unit
plugged in.
upper line
example
Mode 2: Programmable Speed
lower line
PS 5 Programmable speed. There is no external synchronization unit, speed unit or remote unit
plugged in and switched on. At speeds of < 100 fps the last position (1/1000 fps) is displayed.
ESU External synchronization unit is plugged in. The camera recognises whether a valid frame speed
of 5 to 75 fps (5 to 150 fps on the HS camera) is set. If no valid frame speed can be recognised,
the fps symbol flashes.
SU Speed unit or remote unit is plugged in and switched on.
23.45 Programmable speed or speed set by the external synchronization unit, speed unit or remote unit.
At speeds of < 100 fps the positions before the comma and two positions after the comma are
displayed. At speeds of > 100 fps (possible on the HS camera) the positions before the comma
and one position after the comma are displayed.