Symptom-to-FRU index 139
CD-ROM drive
cable is not
plugged in.
1. Make sure CD-ROM drive
cable is plugged in.
Diskette drive in-
use light stays on,
or the system
bypasses the
diskette drive, or
the diskette drive
does not work.
1. If there is a diskette in the
drive, verify that:
a. The diskette drive is
enabled in the
Configuration/Setup
utility program.
b. The diskette is good
and not damaged. (Try
another diskette if you
have one.)
c. The diskette is inserted
correctly in the drive.
d. The diskette contains
the necessary files to
start the server.
e. The software program is
OK.
f. Cable is installed
correctly (proper
orientation)
2. Run Diskette Drive
Diagnostics.
3. Cable
4. Diskette Drive
5. System Board
Monitor problems
(general). Some
IBM monitors have
their own self-tests.
If you suspect a
problem with the
monitor, refer to the
information that
comes with the
monitor for adjusting
and testing
instructions.
1. Monitor
2. Run Video Diagnostics. If
diagnostics pass, the
problem may be a video
driver.
3. Display Adapter / System
Board
General FRU/Action