IBM 31Y Security Camera User Manual


 
142 Netfinity 3500-M20 – Type 8657 Models 21Y, 22Y, 31Y, 32Y,
101, 102, 106
(System and
microprocessor
error)
1. System Board
111
(Channel check
error)
1. Failing adapter
2. DIMM
3. System board
114
(Adapter read-only
memory error)
1. Failing adapter
2. Run diagnostics
129
(Internal cache
error)
1. Microprocessor
2. Optional microprocessor (if
installed)
151
(Real time clock
error)
1. Run Diagnostics
2. Battery
3. System Board
161
(Real time clock
battery error)
1. Run Configuration/Setup
2. Battery
3. System Board
162
(Device
Configuration Error)
Note: Be sure to
load the
default
settings and
any
additional
desired
settings;
then, save
the
configura-
tion.
1. Run Configuration/Setup
2. Battery
3. Failing Device
4. System Board
163
(Real-Time Clock
error)
1. Run Configuration/Setup
2. Battery
3. System Board
164
(Memory
configuration
changed, see
"Memory Settings"
on page 36.)
1. Run Configuration/Setup
2. DIMM
3. Memory Card
4. System Board
175
(Hardware error)
1. System Board
Error
Code/Symptom
FRU/Action