• Page 17 Various setting 4
MIC ADJ :
B :
:
ATW ADJ
R
AUTO(YES )
126
134
89
FILTER :
2
:
PAGE17(NEXT PREV )
EXIT MENU (YES )
ATW ADJ Take in standard value of ATW
R Standard value setting of ATW
B Standard value setting of ATW
MIC ADJ Setting of a musical note mark indication
FILTER Destination setting of filter (standard:2)
Note : In ATW ADJ, it is taken in the calculation standard value of
color temperature when the AUTO WHITE is carried out,
therefore, normally, no adjustment is required.
When the indication value of color temperature is different
from the actual value, confirm the output level of CCD unit.
(How to confirmation : Refer to the SECTION 3
ALIGNMENT “3-3-11. CCD Output Level Adjustment”) If
the output level of CCD unit is different from the
specification, perform the CCD output level adjustment, and
then, take in the standard value to the following procedures;
1. Shoot the pattern of 3200 K color temperature.
2. Set W. BAL switch to "A" position, and perform the
AUTO WHITE balance.
3. Move the cursor to “ATW ADJ” by STATUS/MENU
switch, and press UP
44
44
4 switch.
• Page 18 Selfdiagnosis 1
DIAG ERROR RESET
PAGE18(NEXT PREV )
EXIT MENU (YES )
(YES )
MEMORY BACKUP
(YES )
DIAG ERROR RESET
The results of error check and the history of defective item are erased.
MEMORY BACKUP
The data of EEPROM on the TG, IF and ES boards are made backup
copy to the EEPROM on the MB board.
If the communication between the EEPROM on the TG, IF, ES boards
and microcomputer are abnormal when the power switch turns on, the
data of backup copy on the EEPROM of the MB board is used because
the data held on the EEPROM of TG, IF and ES boards can not be
used.
Therefore, make backup copy, when changing the contents of the menu
page 5 through page 8, page 11 and page 12, or when changing the one
of TG, IF, ES and MB boards.
Note : The DIAG ERROR RESET and MEMORY BACKUP are
carried out when the RESET on the service menu of page 1 is